Injection System ISWVERSIONE 5.0.8 ENG (C.A.D), Auto Gaz Zavoli Alisei, Zavoli

[ Pobierz całość w formacie PDF ]
Injection System
DREAM XXI
Description of the injection system
calibration software
COMPLETE ADVANCED VERSION
Table of Contents
English

Introduction..................................................................................................
3

Main Menu ....................................................................................................
4

VehicleConiguration......................................................................................
5
F1 Change-Over
............................................................................................
6-8
F2 Lambda....................................................................................................
9-10
F3 Emissions.................................................................................................
11
F4 Sensors ...................................................................................................
12-13
F5 Map.........................................................................................................
14-15
F6 Adjustments .............................................................................................
16
F7 Gas/Petrol ................................................................................................
16-17
F8 Modify carb
..............................................................................................
18
Display chart.................................................................................................
19

Display.........................................................................................................
20

Diagnosis .....................................................................................................
21

Autocalibration ..............................................................................................
22

SaveConiguration ........................................................................................
23

LoadConiguration.........................................................................................
23

ECUReprogramming ......................................................................................
24
2 - 25
IswDreamXXI_it-0 Rev. 110509-0
Introduction
English
Minimum computer requirements for software installation
Operatingsystem - Windows982
nd
edition or later versions
Memory(RAM) - Atleast16Mbyte
Harddrive - Atleast20Mbytefreeattimeofinstallation
Displayresolution - 800x600orgreater
Internet Explorer 5.5
orhighermustalsobeinstalled.
Software installation
Toinstallthecalibrationsoftware,puttheCD-ROMinthecomputerdriveandwaitfortheguided
installationwindowtoopen.
Iftheinstallationprogramdoesnotstart,select“Start”inthe“Taskbar”.Choose“Run”andenter:
"D:\setup.exe"(whereDstandsfortheCD-ROMdrive).
Duringinstallationyouwillbeaskedinwhichdirectoryyouwanttoinstalltheprogram.Werecom-
mendyoudonotchangethepre-setdirectoryandrememberitsincetheconiguration,acquisition
andirmwareileswillbesavedinit.
Theprogramiconwillbecreatedonthedesktopwheninstallationiscomplete.
Note: To view the complete advanced version (CAD), you will need to connect the relevant
parallel port or USB port hardware key to the PC.
Introduction
Thecalibrationsoftwarecanbeopenedwithouthavingtobeconnecteddirectlytothecontrolunit.
Toconnecttothecontrolunit,ontheotherhand,thePCandcontrolunitmustbeproperlyconnected
byaninterfacecable(toorderseparatelyasitdoesnotcomeinthekit)andaUSBserialadapter(if
thePCdoesnothaveaserialport),whichcanbepurchasedfromanyITmaterialretailer.
Thecontrolunitmustalsobeconnectedtothe+12voltbattery(red–blackwire)andtotheground
(blackwire).
IswDreamXXI_it-0 Rev. 110509-0
3 - 25
Main Menu
English
Main Menu
Allcalibrationsoftwaresubmenuslistedbelowwiththeirseparatedescriptionscanbeaccessedfrom
thismenu:
File Menu:
Forexitingthecalibra-
tionsoftware.
Connection Menu:
Forconnecting/
disconnectingthegascontrolunit
fromthecalibrationsoftware.
SettingsMenu:
Forselectingthe
calibrationsoftwarelanguagebased
onthecountrywhereused.
Help Menu:
Providesinformation
aboutthesoftwareversioninstalled
andtheexpirationdateofthehard-
warekeyused.
Update on the Internet:
Here
youcanupdatethesoftwareto
thelatestversionavailableusinga
guidedprocedureontheInternet.
Ifupdatedversionsshouldbecome
available,amessagesayinganup-
dateismissingwillbedisplayed.
OpelZaira1.616v
Firmware Version xx
Thefollowinginformationisshownatthebottomofthepage:
1
2
3
4
OpelZaira1.616v
Firmware Version xx
1)indicateswhetherthecontrolunitisconnectedordisconnectedtothecalibrationsoftware.Itis
importanttorememberthatallthesettingsmadeonthedisconnectedcontrolunitwillbelostwhen
itisconnected,unlesstheyarepreviouslysavedinaconigurationile.
Whentheprogramisopenedautomatically,itwilltrytoconnecttothecontrolunit.
Iftheprogramdoesnotconnect,anerrorwindowwillopen.Atthispointcheck:
-theserialinterfaceconnection,
-thatthecontrolunitisconnectedtothebatteryandground,
-ifthesubkeyhasbeendisconnectedformorethananhour,toconnectitwillbenecessaryto
connectthepanelforafewsecondsandcheckthattheswitchturnsonatthesametime,orstart
the vehicle.
Toattemptconnectionagain,openthe“Connection”windowandselect“Connect”.
2)isthenameoftheconigurationinthecontrolunit(max.28charactersdisplayed).Touploada
pre-existingconigurationinthecontrolunit,itmustbeconnectedtotheconigurationsoftware(see
chapter
"Loadconiguration"
).
3)istheirmwareversionofthecontrolunitconnected;toupdateit,gotothesubmenu“REPRO-
GRAMCONTROLUNIT”andselectthedesiredirmwarefromthoseproposed.
Note:ThisoperationispossibleonlyifINTERNETEXPLORER5.5orhigherisinstalled.
4)indicateswhethertheconigurationcurrentlyloadedinthecontrolunitusestheoperationparam-
etersfornaturalgasorforLPG;toselectthefueltype,gotothesubmenu“VEHICLECONFIGURA-
TION”.
4 - 25
IswDreamXXI_it-0 Rev. 110509-0
Vehicle coniguration
English
Thismenuconsistsof8pagesinwhichitispos-
sibletosettheparametersthatmanagethe
behaviourofthegascontrolunitand2pull-down
menussituatedintheupperleft-handcorner:

Coniguration:
Forexitingthevehiclecon-
igurationmenu.
Inthepartunderneathallofthepages,adisplaysummarisingthecurrentvaluesofthegeneralsystemopera-
tionsignalsisprovided
1
2
3
4
5
1)
Whetherthevehicleispetrolorgas-poweredisdisplayedinthisbox;CUT-OFFalsomightappearwhenthe
systemisinthecut-offcondition.
2)
Thefollowingaredisplayedinthisbox:
REVOLUTIONS:
theenginerevolutionsreadinrealtimebythegascontrolunit.
T.GAS:
gastemperaturedetectedbythetemperaturesensorpositionedonthegasinjectionrail.
T.RED:
gasreductiongeartemperaturedetectedbythetemperaturesensorpositionedonthegas
reductiongear.
3)
Thegas(Tinj.gas)andpetrol(Tinj.benz)timesaredisplayedinthisbox.If2banksareselected(seepara-
graph
"F2 Lambda"
),thegasandpetroltimesregardingthesecondbankwillalsobedisplayed.
4)
Thefollowingaredisplayedinthisbox:
GAS PRESS:
thisisthepressuredifferencebetweenthegasinthegasinjectorsandthatintheintake
manifoldsreadbythepressuregaugesuppliedinthekit.
MAP:
IfanAEB025pressuresensorhasbeeninstalled,itidentiiestheintakepressureinthemani-
folds.
AEB025 SENSOR:
indicatesthetypeofpressuregaugethesoftwareselects(seeparagraph
"F4 sen-
sors"
).
5)
Thefollowingaredisplayedinthisbox:
-thevoltageofthe
lambda
probereadbythepurplewire(ifconnected);itisalsonecessarytosetthetype
ofprobeconnected(front/back)in“F2Lambda”.Ifthelatterisnotset,novaluewillbedisplayed(n.d.).
-thevoltageofthe
lambd2a
probereadbythepurple/blackwire(ifconnected);itisalsonecessarytosetthe
typeofprobeconnected(front/back)in“F2Lambda”.Ifthelatterisnotset,novaluewillbedisplayed(n.d.).
-thevaluetheGASinjectioncontrolunitreadsthroughthelevelsensorconnectedtoit(absolutevalue).
IswDreamXXI_it-0 Rev. 110509-0